Changelog

This page contains the five latest stable releases. Older releases and Finnish translations are preserved in the archive.

[Unreleased]

[1.4.6] - 18-11-2026

miniDSP filters that fit the FIR block

With miniDSP ticked, the filters fit the 4096-tap pool of a 2x4 HD or Flex: 2042 taps for two outputs, 1362 with a subwoofer, 1024 with two. Output settings, Setup and START show the limit, and your tap setting stays saved.

[1.4.5] - 18-11-2026

Filters for miniDSP

Tick miniDSP files in Output settings. The FIR then corrects phase only, and PEQ filters carry the EQ, including boosts and room-mode cuts. Set how many per output below the box; the default is 10.

The high-pass goes to the plugin’s crossover block instead of the FIR. The README gives its type and frequency, and the export adds it as biquad files. Export at the plugin’s sample rate. Hybrid IIR and the Equalizer APO, PipeWire, HLC, Roon and JRiver files are unavailable while miniDSP is ticked.

Clearer START page

Pick Standard or All four filter types, tick Automatic tap count for either, then press the one START button. Output settings has its own page in the sidebar, just above START. START shows your output choices in one line, and Change… opens the page.

Filters ready for Roon and JRiver

Tick Roon convolution ZIP or JRiver convolution folder in Output settings. Each holds your filters for every exported rate, so the player switches to the one that matches playback. Roon takes the ZIP as it is. The export then skips the CamillaDSP files, so each filter is saved once. Filters with subwoofer outputs still need CamillaDSP.

Compare filters inside DecayCore

The new Compare FIRs page puts saved filters side by side in the built-in FIR Compare, with each predicted response against the target the run used. Compare filters on the Results page opens it with the run, or the whole batch, selected.

Targets saved with your filters

Each filter ZIP now holds the target each channel was designed for, as a REW-compatible text file. Compare FIRs lists runs saved from this version on. Add older filters as WAV files.

Automatic mode goals now pick different filters

Room-safe now favors less boost and gentler correction, Low-ripple the smoothest bass, and Subwoofers the closest match to the target from 20 to 200 Hz. Before, all three picked the same filter as Balanced 90% of the time. Balanced is unchanged. Earlier Automatic results are rebuilt.

Measurements on macOS record to the end

On macOS the microphone could stop a moment into the sweep while playback went on, and the measurement timed out. DecayCore no longer checks audio devices during a measurement, which is what stopped the recording. Thanks to PaulZH from ASR-forum for helping solve this.

Bass phase correction no longer fades run by run

Automatic mode no longer weakens bass phase correction a little more on every run. It could fade to zero, leaving the FIR with no bass phase correction. Earlier Automatic results are rebuilt.

Full bass from short filters

Short filters no longer roll off the bass. At 2048 taps and 96 kHz they lost about 4 dB at 20 Hz and 25 dB at 5 Hz. Earlier Automatic results are rebuilt.

Hybrid IIR only with CamillaDSP alone

Hybrid IIR can’t be ticked while Output settings adds Equalizer APO, PipeWire, HLC, Roon or JRiver files. Those play the FIR alone and would miss the IIR cuts. The setup panel shows when Hybrid IIR is on.

Equalizer APO, PipeWire and HLC files ticked separately

Output settings now has one box each for the Equalizer APO, PipeWire and HLC convolver files. If you had ticked the shared Equalizer APO and PipeWire box, both stay on. HLC files are no longer added unless you tick them.

Faster Linear Phase calculation

Linear Phase filters calculate about 25% faster. The filters are unchanged.

[1.4.4] - 13-11-2026

Intel Macs get their own package

Releases now include a macOS package for Intel Macs next to the Apple silicon one. Download the one that matches your Mac.

Phase correction works better

Automatic mode keeps the phase correction unless dropping it clearly helps, and the group-delay limiter now covers the bass too, so room modes near 30 Hz no longer slip through. If the limiter’s result is still too strong, the correction is scaled down until it fits.

Resonances are cut deeper

Automatic mode now judges tone at matched level, so room-mode peaks come down 0.5 to 1.6 dB further on a reference measurement. A resonance that is cut until its decay can no longer be measured counts as fixed.

Left and right stay balanced

With stereo link on, both channels keeps balance better compared to each other.

Measurement starts with your default devices

The Measure page now selects your system’s default microphone and output when you have no saved choice.

Faster Automatic mode on Windows

Automatic mode runs about 15% faster on Windows.

Record test for audio problems

If measurement stops recording, start DC with : --audio-record-test extension in a terminal. It records three seconds through two audio paths and prints which one works. Send the output with your log file. Command works at every OS.

Quicker error when the input stops

If the microphone stops delivering audio during a measurement, DecayCore now gives up after a few seconds of silence instead of waiting for each retry to time out. The log file also records why a measurement failed.

[1.4.3] - 30-10-2026

Send a log file with bug reports

Tick Save a log file in About DecayCore, repeat the problem, and click Email the log. Your email app opens a draft to the developer. Attach the newest file from Documents/DecayCore/logs, since an email link cannot attach it.

Audio diagnostics and LAN access on macOS

Run ./Start_Decay.command --audio-diagnostics to list your audio devices, or --lan to open DecayCore from another computer. With --lan the addresses print in the terminal, macOS asks for microphone access for Terminal, and closing the terminal stops DecayCore.

Placement hints for deep bass nulls

Results lists up to three deep, narrow nulls that no filter can fill, each with the distance to a reflecting surface that can cause it. Moving the speaker, subwoofer or seat does more than any filter.

Settings files for Equalizer APO and PipeWire

Tick Equalizer APO and PipeWire files in Output settings to add a ready-made config for each player to the export, next to the CamillaDSP files.

Profiles for your settings

Save your settings under a name on the Setup page and load them again, for music and movies for example. A profile holds settings only, not measurement files. Undo restores what a load replaced.

Results lead with graphs

Results opens with the graphs. The details sit in three groups, and the ZIP download is a small link beside the saved folder.

Crossover models no longer fail the safety check

Asymmetric and Linear Phase filters for a speaker with crossovers set under XO pass the safety check. Undoing a crossover’s phase puts part of the pulse just ahead of its peak, and the check counted that as pre-ringing. It now allows for it. Earlier Automatic results are rebuilt.

Automatic tap count shortens many more filters

Most Minimum and Mixed Phase filters now shorten by about 60%, Linear Phase filters by about a third, and more Asymmetric filters shorten too. An exported filter stays within 1% (about 0.09 dB) of the design response. The search takes a few seconds longer.

DecayCore asks before quitting mid-run

The Quit button asks first while a run or measurement is in progress, and the browser warns before you close the tab. A long Automatic search is no longer lost by accident.

Undo for Apply mode defaults

Undo puts back the values that Apply mode defaults replaced. The message tells you how many values changed.

Measure says why capture is unavailable

The Measure page shows the reason above the buttons, such as no microphone or output device, and points to loading measurements you already have.

Edit manually from Automatic mode

Pages that Automatic mode manages have an Edit manually in Advanced mode button. In the Modern and North styles their tabs are labelled Auto. The Target preview says when its curve is for reference only.

In the Modern and North styles, tabs are grouped as Prepare, Fine-tune and Run, and each page before START ends with a Next button. The group names show in windows tall enough to fit them.

Run all four filter types keeps every result

Each filter type’s result and download stay on the page, one section per type, with the latest open. Before, only the last result remained.

A tidier XO page and labels

The XO page shows the crossovers you use plus one empty slot, and its heading no longer repeats the step number. Labels no longer use emoji, so they look the same on every system.

[1.4.2] - 24-10-2026

Deep bass nulls now show clearly in the target curve

The target curve dips where the room has a deep null, so the filter no longer tries to fill it. In a test, a 16 dB dip half an octave wide, typical of a boundary cancellation, left the target unchanged. It now lowers the target by about 8 dB. Broad dips and ordinary ripple are left to the correction. A file exported in SPL now gives the same filter as one in dBFS. Earlier Automatic results are rebuilt.

CamillaDSP files no longer cut the level by a fixed 6 dB

Without a subwoofer, the file plays 6 dB louder at the same volume, so lower your volume before the first listen. With a subwoofer, it cuts 6.02 dB for the summed channels, plus any gain from the sub trim. Raise Auto Headroom Margin for more clipping headroom.

Linkwitz-Riley or Butterworth for each crossover

Pick Butterworth or Linkwitz-Riley for each crossover on the XO tab, to match your speakers. Butterworth stays the default.

Results check your crossovers against the measurement

Results shows how well each crossover matches the measured phase, for example “80Hz: 91% good”, and warns when the measurement doesn’t contain one. Crossovers too subtle to see in a room read “not verifiable”. The check never changes the filter.

Finer bass resolution in the analysis

Third-octave smoothing no longer flattens narrow room modes. A 9 dB mode with a Q of 30 now reads 8 dB instead of 3 dB. Filters for smooth measurements are unchanged. Earlier Automatic results are rebuilt.

Implausible room-decay readings no longer shape Bass-first AI or Hybrid IIR

With Bass-first AI on, a measured RT60 that DecayCore already rejects, such as 0.04 s or 8 s, no longer sets the modal limit or narrows the Hybrid IIR band. Earlier Automatic results are rebuilt.

High-pass filters attenuate as designed in Asymmetric and Mixed Phase

A 20 Hz, 24 dB/oct high-pass gave 12 dB at 10 Hz instead of 23 dB. Results now checks the exported high-pass against the one you set. Earlier Automatic results are rebuilt.

Automatic mode keeps high-pass and low-pass filters at full depth

A late refinement step no longer limits their stopband to Max Cut. A 40 Hz, 24 dB/oct high-pass with 131,072 taps now attenuates 10 Hz by 42 dB instead of 17 dB. Earlier Automatic results that used this step are rebuilt.

Low crossovers keep an Asymmetric filter’s response

With a crossover at 100 Hz or lower, an Asymmetric filter could bend the bass by 4 dB or more. It now keeps its designed response, as Linear Phase already does. Earlier Automatic results that used a crossover are rebuilt.

[1.4.1] - 23-10-2026

Group-delay gradient readout covers the audio band

The Results tab and the text report now measure the excess-phase group-delay gradient from 20 Hz up, so its peak is no longer reported at a few hertz. The filters and Automatic mode ranking are unchanged.

Faster bass decay check

When a left/right filter lengthens bass decay, DecayCore tries lighter phase correction. Those attempts now reuse the correction already calculated, so a 65,536-tap Asymmetric run at 44.1 kHz finishes about a third sooner. The filters are identical to before.

Faster, clearer measurement timeout errors

When the audio stream never starts, a measurement now gives up after two seconds instead of waiting out the whole sweep, so a failing device no longer holds the start of the sweep back by about 30 seconds. The error says whether the input device delivered any audio. On macOS, if it delivered none, it points to System Settings > Privacy & Security > Microphone. The log lists the devices that were opened and how many frames were played and recorded.

macOS launcher asks for microphone access as DecayCore

Start_Decay.command now opens the app bundle instead of running it inside Terminal. The microphone prompt and the entry in Privacy & Security name DecayCore, not Terminal.

Crossovers no longer distort the filter

With a crossover set on the XO tab, Asymmetric and Linear Phase filters could cut the midrange by about 20 dB if dB/oct was over 12. The filter now keeps the frequency response it was designed with, and Automatic mode ranks these runs like any others. Earlier Automatic results that used a crossover are rebuilt. Thanks Nomid from ASR-forum to finding this!

Sample-rate ranking matches Automatic mode

When you export several sample rates, the summary ranks them using the same DSP quality penalty as Automatic mode. Scores can differ from earlier versions.

Text measurements with a byte-order mark

Text measurement files saved with a byte-order mark now keep their first data row, and UTF-16 files are read instead of rejected.

Runs with an empty correction band

If the correction band ends up empty, for example when its maximum is below its minimum, the run now finishes without magnitude correction instead of failing.

Corrupt WAV measurements are rejected

A float WAV that contains invalid samples is now reported as unreadable. It used to load as an empty curve and fail later in the run.

Zero values stay zero

A left IR window of 0 ms and a maximum boost of 0 dB are kept when you reopen the app. Both used to snap back to their defaults.

Headroom across the full filter

Final filters keep the requested headroom across the full frequency range, including output tilt and normalization. Reports show any extra attenuation.

More reliable timing with limited measurements

Timing estimates use phase within the measured frequency range. Reports explain when there is too little phase coverage to estimate timing.

Faster Bass Integration calculations

Bass Integration calculates timing faster. Band analysis uses the correct response for odd filter orders.

More dependable correction

Final filter checks catch bass and voice-band peaks in either channel. Bass analysis recognises nearby resonances across sample rates and filter lengths. Correction uses measured room decay; magnitude-derived RT60 estimates remain diagnostic.

Consistent repeated calculations

Changing measurement data no longer alters earlier cached inputs. RT60 estimates stay consistent across filter lengths and calculation order. Earlier Automatic mode results are rebuilt.

Faster Mixed Phase calculation

Mixed Phase filters calculate faster, with pre-ringing protection and alignment checks in place.

Bass Integration for up to four subwoofers

Measure and integrate up to four subs, with previews and results for each one. Separate filters include individual delay, level and polarity, with a six-output CamillaDSP export for four subs and two main speakers. Combined level estimates account for measured level differences and phase cancellation.